CyberSecBulletin
CVE-2005-2773Exploited in the wildNVD status: Analyzed

HP OpenView Network Node Manager Remote Code Execution

CVE-2005-2773 is a critical-severity improper neutralization of special elements used in a command vulnerability in Openview Network Node Manager from HP, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Openview Network Node Manager versions: 6.2 through 7.50. The record does not name a fixed version, so check the vendor advisory. CISA added it to the Known Exploited Vulnerabilities catalogue on March 25, 2022, which means attacks have been observed in the wild.

Patch now

Attackers are already exploiting this vulnerability, according to CISA.

What to do

  1. Check which version of Openview Network Node Manager you run against the affected versions below, and install the vendor's latest release.
  2. CISA's required action: Apply updates per vendor instructions.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
HPOpenview Network Node Manager6.2 through 7.50Not stated

Version data comes from NVD's product matching. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.19.8CriticalNVD
CVSS 3.19.8CriticalCISA (ADP)
CVSS 2.07.5HighNVD

Official description

HP OpenView Network Node Manager 6.2 through 7.50 allows remote attackers to execute arbitrary commands via shell metacharacters in the (1) node parameter to connectedNodes.ovpl, (2) cdpView.ovpl, (3) freeIPaddrs.ovpl, and (4) ecscmg.ovpl.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in a Command

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • If possible, ensure that all external commands called from the program are statically created.
  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.

More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)

Timeline

  1. CVE record published.
  2. Added to CISA's Known Exploited Vulnerabilities catalogue.
  3. Deadline for US federal agencies to remediate, set by CISA.
  4. CISA published its SSVC assessment (exploitation: active, automatable: yes, technical impact: total).
  5. Record last changed materially (score, affected products, status or references).

References

Technical write-ups (may include proof of concept)

Other references

Spotted an error? Tell us.