CyberSecBulletin
CVE-2018-9276Exploited in the wildNVD status: Analyzed

Paessler PRTG Network Monitor OS Command Injection

CVE-2018-9276 is a high-severity improper neutralization of special elements used in an OS command vulnerability in Prtg Network Monitor from Paessler, with a CVSS 3.1 base score of 7.2 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. The record lists versions 18.2.39, 21.2.68 as the first without the flaw, so updating Prtg Network Monitor to one of those releases or later removes the exposure. CISA added it to the Known Exploited Vulnerabilities catalogue on February 4, 2025, which means attacks have been observed in the wild.

Patch now

Attackers are already exploiting this vulnerability, according to CISA.

What to do

  1. Update Prtg Network Monitor to 18.2.39 or 21.2.68, whichever matches your release line, or a later version.
  2. CISA's required action: Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

Affected products and versions

VendorProductAffected versionsFixed in
PaesslerPrtg Network Monitorbefore 18.2.39; after 19.3.52 up to, but not including, 21.2.6818.2.39, 21.2.68

Version data comes from NVD's product matching. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
HighAdministrator-level access is required first.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.2HighNVD
CVSS 3.17.2HighCISA (ADP)
CVSS 2.09.0HighNVD

Official description

An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in an OS Command

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • For any data that will be used to generate a command to be executed, keep as much of that data out of external control as possible. For example, in web applications, this may require storing the data locally in the session's state instead of sending it out to the client in a hidden form field.
  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

More Improper Neutralization of Special Elements used in an OS Command vulnerabilities (CWE-78)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: active, automatable: no, technical impact: total).
  3. Added to CISA's Known Exploited Vulnerabilities catalogue.
  4. Deadline for US federal agencies to remediate, set by CISA.
  5. Record last changed materially (score, affected products, status or references).

References

Patches and release notes

Third-party and government advisories

Technical write-ups (may include proof of concept)

Other vulnerabilities in Prtg Network Monitor

All Prtg Network Monitor vulnerabilities

Recent Improper Neutralization of Special Elements used in an OS Command vulnerabilities

Spotted an error? Tell us.