CyberSecBulletin
CVE-2022-2302NVD status: Modified

cabinet c520: Improper Authentication

CVE-2022-2302 is a critical-severity improper authentication vulnerability in cabinet c520 from Lenze, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version V01.08.01.3021 as the first without the flaw, so updating cabinet c520 to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 2.19% chance of exploitation within 30 days, higher than 83% of scored CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Update cabinet c520 to V01.08.01.3021 or a later version.
  2. Update cabinet c550 to V01.08.01.3021 or a later version.
  3. Update cabinet c750 to V01.08.01.3021 or a later version.
  4. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
LENZEcabinet c520V01.07.00.2757 up to, but not including, V01.08.01.3021V01.08.01.3021
LENZEcabinet c550V01.07.00.2757 up to, but not including, V01.08.01.3021V01.08.01.3021
LENZEcabinet c750V01.07.00.2757 up to, but not including, V01.08.01.3021V01.08.01.3021
LenzeC520 Firmware1.07.00.2757 up to, but not including, 01.08.01.302101.08.01.3021
LenzeC550 Firmware1.07.00.2757 up to, but not including, 01.08.01.302101.08.01.3021
LenzeC750 Firmware1.07.00.2757 up to, but not including, 01.08.01.302101.08.01.3021

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.19.8CriticalCNA (cert.vde.com)
CVSS 3.19.8CriticalNVD
CVSS 2.09.3HighNVD

Official description

Multiple Lenze products of the cabinet series skip the password verification upon second login. After a user has been logged on to the device once, a remote attacker can get full access without knowledge of the password.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Authentication

When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.

How developers prevent this class of flaw

  • Use an authentication framework or library such as the OWASP ESAPI Authentication feature.

More Improper Authentication vulnerabilities (CWE-287)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).

References

Patches and release notes

Recent Improper Authentication vulnerabilities

Spotted an error? Tell us.