CyberSecBulletin
CVE-2022-23449NVD status: Modified

SIMATIC Energy Manager Basic: Uncontrolled Search Path Element

CVE-2022-23449 is a high-severity uncontrolled search path element vulnerability in SIMATIC Energy Manager Basic from Siemens, with a CVSS 3.1 base score of 7.3 out of 10. It can be exploited with local access to the system by an attacker with a low-privileged account, but only if a user takes part, for example by opening a link or file. Affected SIMATIC Energy Manager Basic versions: All versions < V7.3 Update 1. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.33% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of SIMATIC Energy Manager Basic you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on cert-portal.siemens.com for workarounds and exact fixed builds.
  3. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensSIMATIC Energy Manager BasicAll versions < V7.3 Update 1Not stated
SiemensSIMATIC Energy Manager PROAll versions < V7.3 Update 1Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.3HighNVD
CVSS 2.06.9MediumNVD

Official description

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Uncontrolled Search Path Element

The product uses a fixed or controlled search path to find resources, but one or more locations in that path can be under the control of unintended actors.

How developers prevent this class of flaw

  • Hard-code the search path to a set of known-safe values (such as system directories), or only allow them to be specified by the administrator in a configuration file. Do not allow these settings to be modified by an external party. Be careful to avoid related weaknesses such as CWE-426 and CWE-428.
  • When invoking other programs, specify those programs using fully-qualified pathnames. While this is an effective approach, code that uses fully-qualified pathnames might not be portable to other systems that do not use the same pathnames. The portability can be improved by locating the full-qualified paths in a centralized, easily-modifiable location within the source code, and having the code refer to these paths.
  • Remove or restrict all environment settings before invoking other programs. This includes the PATH environment variable, LD_LIBRARY_PATH, and other settings that identify the location of code libraries, and any application-specific search paths.

More Uncontrolled Search Path Element vulnerabilities (CWE-427)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in SIMATIC Energy Manager Basic

All SIMATIC Energy Manager Basic vulnerabilities

Recent Uncontrolled Search Path Element vulnerabilities