Inet 900 Firmware: Download of Code Without Integrity Check

CVE-2022-24117 is a critical-severity download of code without integrity check vulnerability in Inet 900 Firmware from Ge, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version 8.3.0 as the first without the flaw, so updating Inet 900 Firmware to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.37% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Update Inet 900 Firmware to 8.3.0 or a later version.
  2. Update Inet Ii 900 Firmware to 8.3.0 or a later version.
  3. Update Sd2 Firmware to 6.4.7 or a later version.
  4. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
GeInet 900 Firmwarebefore 8.3.08.3.0
GeInet Ii 900 Firmwarebefore 8.3.08.3.0
GeSd1 Firmware6.4.7 and earlierNot stated
GeSd2 Firmwarebefore 6.4.76.4.7
GeSd4 Firmwarebefore 6.4.76.4.7
GeSd9 Firmwarebefore 6.4.76.4.7
GeTd220max Firmwarebefore 1.2.61.2.6
GeTd220x Firmwarebefore 2.0.162.0.16

Version data comes from NVD's product matching. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.19.8CriticalNVD
CVSS 3.19.8CriticalCISA (ADP)

Official description

Certain General Electric Renewable Energy products download firmware without an integrity check. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Download of Code Without Integrity Check

The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code.

How developers prevent this class of flaw

  • Perform proper forward and reverse DNS lookups to detect DNS spoofing.
  • Encrypt the code with a reliable encryption scheme before transmitting.
  • Run your code using the lowest privileges that are required to accomplish the necessary tasks. If possible, create isolated accounts with limited privileges that are only used for a single task. That way, a successful attack will not immediately give the attacker access to the rest of the software or its environment. For example, database applications rarely need to run as the database administrator, especially in day-to-day operations.

More Download of Code Without Integrity Check vulnerabilities (CWE-494)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Patches and release notes

Other vulnerabilities in Inet 900 Firmware

All Inet 900 Firmware vulnerabilities

Recent Download of Code Without Integrity Check vulnerabilities

Spotted an error? Tell us.