CVE-2022-24296NVD status: Modified

Air Conditioning System G-150AD; Air…: Use of a Broken or Risky Cryptographic Algorithm

CVE-2022-24296 is a high-severity use of a broken or risky cryptographic algorithm vulnerability in Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A versions: Air Conditioning System G-150AD Ver. 3.21 and prior; Air Conditioning System AG-150A-A Ver. 3.21 and prior; Air Conditioning System AG-150A-J Ver. 3.21 and prior, and others listed below. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.17% chance of exploitation within 30 days, higher than 68% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on mee.co.jp for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50AAir Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50AAir Conditioning System G-150AD Ver. 3.21 and prior; Air Conditioning System AG-150A-A Ver. 3.21 and prior; Air Conditioning System AG-150A-J Ver. 3.21 and prior; Air Conditioning System GB-50AD Ver. 3.21 and prior; Air Conditioning System GB-50ADA-A Ver. 3.21 and prior; Air Conditioning System GB-50ADA-J Ver. 3.21 and prior; Air Conditioning System EB-50GU-A Ver. 7.10 and prior; Air Conditioning System EB-50GU-J Ver. 7.10 and prior; and 12 more rangesNot stated
MitsubishiAe-200a Firmware7.97 and earlierNot stated
MitsubishiAe-200e Firmware7.97 and earlierNot stated
MitsubishiAe-200j Firmware7.97 and earlierNot stated
MitsubishiAe-50a Firmware7.97 and earlierNot stated
MitsubishiAe-50e Firmware7.97 and earlierNot stated
MitsubishiAe-50j Firmware7.97 and earlierNot stated
MitsubishiAg-150a-a Firmware3.21 and earlierNot stated
MitsubishiAg-150a-j Firmware3.21 and earlierNot stated
MitsubishiEb-50gu-a Firmware7.10 and earlierNot stated
MitsubishiEb-50gu-j Firmware7.10 and earlierNot stated
MitsubishiEw-50a Firmware7.97 and earlierNot stated
MitsubishiEw-50e Firmware7.97 and earlierNot stated
MitsubishiEw-50j Firmware7.97 and earlierNot stated
MitsubishiG-150ad Firmware3.21 and earlierNot stated
MitsubishiGb-50a Firmware3.21 and earlierNot stated
MitsubishiGb-50ada-a Firmware3.21 and earlierNot stated
MitsubishiGb-50ada-j Firmware3.21 and earlierNot stated
MitsubishiTe-200a Firmware7.97 and earlierNot stated
MitsubishiTe-50a Firmware7.97 and earlierNot stated
MitsubishiTw-50a Firmware7.97 and earlierNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
NoneNothing can be modified.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.5HighNVD
CVSS 2.05.0MediumNVD

Official description

Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Use of a Broken or Risky Cryptographic Algorithm

The product uses a broken or risky cryptographic algorithm or protocol.

How developers prevent this class of flaw

  • Ensure that the design allows one cryptographic algorithm to be replaced with another in the next generation or version. Where possible, use wrappers to make the interfaces uniform. This will make it easier to upgrade to stronger algorithms. With hardware, design the product at the Intellectual Property (IP) level so that one cryptographic algorithm can be replaced with another in the next generation of the hardware product.
  • Carefully manage and protect cryptographic keys (see CWE-320). If the keys can be guessed or stolen, then the strength of the cryptography itself is irrelevant.
  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. Industry-standard implementations will save development time and may be more likely to avoid errors that can occur during implementation of cryptographic algorithms. Consider the ESAPI Encryption feature.

More Use of a Broken or Risky Cryptographic Algorithm vulnerabilities (CWE-327)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).