Fidelis Network: Improper Neutralization of Special Elements used in a Command
CVE-2022-24389 is a high-severity improper neutralization of special elements used in a command vulnerability in Fidelis Network from Fidelis Cybersecurity, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. The record lists version 9.4.5 as the first without the flaw, so updating Fidelis Network to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 1.53% chance of exploitation within 30 days, higher than 75% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update Fidelis Network to 9.4.5 or a later version.
- Update Fidelis Deception to 9.4.5 or a later version.
- Update Deception to 9.4.5 or a later version.
- Read the advisory on fidelissecurity.zendesk.com for workarounds and exact fixed builds.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Fidelis Cybersecurity | Fidelis Network | Fidelis Network up to, but not including, 9.4.5 | 9.4.5 |
| Fidelis Cybersecurity | Fidelis Deception | Fidelis Deception up to, but not including, 9.4.5 | 9.4.5 |
| Fidelissecurity | Deception | before 9.4.5 | 9.4.5 |
| Fidelissecurity | Network | before 9.4.5 | 9.4.5 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- LowA basic user account is enough.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 3.1 | 8.8 | High | CNA (fidelissecurity.com) |
| CVSS 3.1 | 8.8 | High | NVD |
| CVSS 2.0 | 9.0 | High | NVD |
Official description
Vulnerability in rconfig “cert_utils” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- Record last changed materially (score, affected products, status or references).
References
Advisories
- fidelissecurity.zendesk.com/hc/en-us/articles/6211730139411Permissions Required
Other vulnerabilities in Fidelis Network
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 7.2 High severity
- 9.1 Critical severity
- 8.8 High severity
- 8.8 High severity
- 9.8 Critical severity
- 9.8 Critical severity
Spotted an error? Tell us.