CyberSecBulletin
CVE-2022-27868NVD status: Modified

Autodesk Advanced Steel, Civil 3D, AutoCAD…: Use After Free

CVE-2022-27868 is a high-severity use after free vulnerability in Autodesk Advanced Steel, Civil 3D, AutoCAD, AutoCAD LT, AutoCAD Architecture, AutoCAD Electrical, AutoCAD Map 3D, AutoCAD Mechanical, AutoCAD MEP, AutoCAD Plant 3D, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected Autodesk Advanced Steel, Civil 3D, AutoCAD, AutoCAD LT, AutoCAD Architecture, AutoCAD Electrical, AutoCAD Map 3D, AutoCAD Mechanical, AutoCAD MEP, AutoCAD Plant 3D versions: 2023. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.17% chance of exploitation within 30 days, higher than 68% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Autodesk Advanced Steel, Civil 3D, AutoCAD, AutoCAD LT, AutoCAD Architecture, AutoCAD Electrical, AutoCAD Map 3D, AutoCAD Mechanical, AutoCAD MEP, AutoCAD Plant 3D you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on autodesk.com for workarounds and exact fixed builds.
  3. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.8HighNVD
CVSS 2.06.8MediumNVD

Official description

A maliciously crafted CAT file in Autodesk AutoCAD 2023 can be used to trigger use-after-free vulnerability. Exploitation of this vulnerability may lead to code execution.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Use After Free

The product reuses or references memory after it has been freed. At some point afterward, the memory may be allocated again and saved in another pointer, while the original pointer references a location somewhere within the new allocation. Any operations using the original pointer are no longer valid because the memory belongs to the code that operates on the new pointer.

How developers prevent this class of flaw

  • Choose a language that provides automatic memory management.
  • When freeing pointers, be sure to set them to NULL once they are freed. However, the utilization of multiple or complex data structures may lower the usefulness of this strategy.

More Use After Free vulnerabilities (CWE-416)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in Autodesk Advanced Steel, Civil 3D, AutoCAD, AutoCAD LT, AutoCAD Architecture, AutoCAD Electrical, AutoCAD Map 3D, AutoCAD Mechanical, AutoCAD MEP, AutoCAD Plant 3D

All Autodesk Advanced Steel, Civil 3D, AutoCAD, AutoCAD LT, AutoCAD Architecture, AutoCAD Electrical, AutoCAD Map 3D, AutoCAD Mechanical, AutoCAD MEP, AutoCAD Plant 3D vulnerabilities

Recent Use After Free vulnerabilities

Spotted an error? Tell us.