CyberSecBulletin
CVE-2022-29607NVD status: Modified

Onos: Always-Incorrect Control Flow Implementation

CVE-2022-29607 is a high-severity always-incorrect control flow implementation vulnerability in Onos from Opennetworking, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Onos versions: 2.5.1. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.67% chance of exploitation within 30 days, higher than 52% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Onos you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
OpennetworkingOnos2.5.1Not stated

Version data comes from NVD's product matching. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
NoneNo data is disclosed.
Integrity
HighData or code can be modified at will.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.5HighNVD
CVSS 3.17.5HighCISA (ADP)

Official description

An issue was discovered in ONOS 2.5.1. Modification of an existing intent to have the same source and destination shows the INSTALLED state without any flow rule. Improper handling of such an intent is misleading to a network operator.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Always-Incorrect Control Flow Implementation

The code contains a control flow path that does not reflect the algorithm that the path is intended to implement, leading to incorrect behavior any time this path is navigated.

More Always-Incorrect Control Flow Implementation vulnerabilities (CWE-670)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Technical write-ups (may include proof of concept)

Other vulnerabilities in Onos

All Onos vulnerabilities

Recent Always-Incorrect Control Flow Implementation vulnerabilities

Spotted an error? Tell us.