CyberSecBulletin
CVE-2022-3094NVD status: Modified

BIND 9: Use After Free

CVE-2022-3094 is a high-severity use after free vulnerability in BIND 9 from ISC, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected BIND 9 versions: 9.16.0 through 9.16.36; 9.18.0 through 9.18.10; 9.19.0 through 9.19.8, and others listed below. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 13.2% chance of exploitation within 30 days, which is in the top 3.56% of all scored CVEs.

Patch this week

EPSS places it among the vulnerabilities most likely to be exploited soon.

What to do

  1. Update Bind to 9.16.37 or 9.18.11 or 9.19.9, whichever matches your release line, or a later version.
  2. Read the advisory on kb.isc.org for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
ISCBIND 99.16.0 through 9.16.36; 9.18.0 through 9.18.10; 9.19.0 through 9.19.8; 9.16.8-S1 through 9.16.36-S1Not stated
ISCBind9.16.0 up to, but not including, 9.16.37; 9.18.0 up to, but not including, 9.18.11; 9.19.0 up to, but not including, 9.19.9; 9.16.8; 9.16.11; 9.16.13; 9.16.14; 9.16.21; and 2 more ranges9.16.37, 9.18.11, 9.19.9

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
NoneNo data is disclosed.
Integrity
NoneNothing can be modified.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.5HighCNA (isc.org)
CVSS 3.17.5HighNVD

Official description

Sending a flood of dynamic DNS updates may cause `named` to allocate large amounts of memory. This, in turn, may cause `named` to exit due to a lack of free memory. We are not aware of any cases where this has been exploited. Memory is allocated prior to the checking of access permissions (ACLs) and is retained during the processing of a dynamic update from a client whose access credentials are accepted. Memory allocated to clients that are not permitted to send updates is released immediately upon rejection. The scope of this vulnerability is limited therefore to trusted clients who are permitted to make dynamic zone changes. If a dynamic update is REFUSED, memory will be released again very quickly. Therefore it is only likely to be possible to degrade or stop `named` by sending a flood of unaccepted dynamic updates comparable in magnitude to a query flood intended to achieve the same detrimental outcome. BIND 9.11 and earlier branches are also affected, but through exhaustion of internal resources rather than memory constraints. This may reduce performance but should not be a significant problem for most servers. Therefore we don't intend to address this for BIND versions prior to BIND 9.16. This issue affects BIND 9 versions 9.16.0 through 9.16.36, 9.18.0 through 9.18.10, 9.19.0 through 9.19.8, and 9.16.8-S1 through 9.16.36-S1.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Use After Free

The product reuses or references memory after it has been freed. At some point afterward, the memory may be allocated again and saved in another pointer, while the original pointer references a location somewhere within the new allocation. Any operations using the original pointer are no longer valid because the memory belongs to the code that operates on the new pointer.

How developers prevent this class of flaw

  • Choose a language that provides automatic memory management.
  • When freeing pointers, be sure to set them to NULL once they are freed. However, the utilization of multiple or complex data structures may lower the usefulness of this strategy.

More Use After Free vulnerabilities (CWE-416)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in BIND 9

All BIND 9 vulnerabilities

Recent Use After Free vulnerabilities

Spotted an error? Tell us.