CVE-2022-31765NVD status: Modified

RUGGEDCOM RM1224 LTE(4G) EU: Missing Authorization

CVE-2022-31765 is a high-severity missing authorization vulnerability in RUGGEDCOM RM1224 LTE(4G) EU from Siemens, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. The record lists version V7.1.2 as the first without the flaw, so updating RUGGEDCOM RM1224 LTE(4G) EU to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 1.1% chance of exploitation within 30 days, higher than 66% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update RUGGEDCOM RM1224 LTE(4G) EU to V7.1.2 or a later version.
  2. Update RUGGEDCOM RM1224 LTE(4G) NAM to V7.1.2 or a later version.
  3. Update SCALANCE M804PB to V7.1.2 or a later version.
  4. Read the advisory on cert-portal.siemens.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensRUGGEDCOM RM1224 LTE(4G) EUbefore V7.1.2V7.1.2
SiemensRUGGEDCOM RM1224 LTE(4G) NAMbefore V7.1.2V7.1.2
SiemensSCALANCE M804PBbefore V7.1.2V7.1.2
SiemensSCALANCE M812-1 ADSL-Routerbefore V7.1.2V7.1.2
SiemensSCALANCE M816-1 ADSL-Routerbefore V7.1.2V7.1.2
SiemensSCALANCE M826-2 SHDSL-Routerbefore V7.1.2V7.1.2
SiemensSCALANCE M874-2before V7.1.2V7.1.2
SiemensSCALANCE M874-3before V7.1.2V7.1.2
SiemensSCALANCE M876-3before V7.1.2V7.1.2
SiemensSCALANCE M876-3 (ROK)before V7.1.2V7.1.2
SiemensSCALANCE M876-4before V7.1.2V7.1.2
SiemensSCALANCE M876-4 (EU)before V7.1.2V7.1.2
SiemensSCALANCE M876-4 (NAM)before V7.1.2V7.1.2
SiemensSCALANCE MUM853-1 (EU)before V7.1.2V7.1.2
SiemensSCALANCE MUM856-1 (EU)before V7.1.2V7.1.2
SiemensSCALANCE MUM856-1 (RoW)before V7.1.2V7.1.2
SiemensSCALANCE S615 EEC LAN-Routerbefore V7.1.2V7.1.2
SiemensSCALANCE S615 LAN-Routerbefore V7.1.2V7.1.2
SiemensSCALANCE SC622-2CAll versions < V3.0Not stated
SiemensSCALANCE SC632-2CAll versions < V3.0Not stated
SiemensSCALANCE SC636-2CAll versions < V3.0Not stated
SiemensSCALANCE SC642-2CAll versions < V3.0Not stated
SiemensSCALANCE SC646-2CAll versions < V3.0Not stated
SiemensSCALANCE W1748-1 M12all versionsNot stated
SiemensSCALANCE W1788-1 M12all versionsNot stated

Version data comes from the organisation that assigned the CVE; 35 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.18.8HighCNA (siemens.com)
CVSS 3.18.8HighNVD

Official description

Affected devices do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Missing Authorization

The product does not perform an authorization check when an actor attempts to access a resource or perform an action.

How developers prevent this class of flaw

  • Divide the product into anonymous, normal, privileged, and administrative areas. Reduce the attack surface by carefully mapping roles with data and functionality. Use role-based access control (RBAC) to enforce the roles at the appropriate boundaries. Note that this approach may not protect against horizontal authorization, i.e., it will not protect a user from attacking others with the same role.
  • Ensure that access control checks are performed related to the business logic. These checks may be different than the access control checks that are applied to more generic resources such as files, connections, processes, memory, and database records. For example, a database may restrict access for medical records to a specific database user, but each record might only be intended to be accessible to the patient and the patient's doctor.
  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. For example, consider using authorization frameworks such as the JAAS Authorization Framework and the OWASP ESAPI Access Control feature.

More Missing Authorization vulnerabilities (CWE-862)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in RUGGEDCOM RM1224 LTE(4G) EU

All RUGGEDCOM RM1224 LTE(4G) EU vulnerabilities

Recent Missing Authorization vulnerabilities

Spotted an error? Tell us.