CyberSecBulletin
CVE-2022-32664NVD status: Modified

EN7516, EN7528, EN7529, EN7561, EN7562, EN7580: Improper Neutralization of Special Elements used in a Command

CVE-2022-32664 is a high-severity improper neutralization of special elements used in a command vulnerability in EN7516, EN7528, EN7529, EN7561, EN7562, EN7580 from MediaTek, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected EN7516, EN7528, EN7529, EN7561, EN7562, EN7580 versions: Linux SDK versions less than TLM-7.3.293.0. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.21% chance of exploitation within 30 days, higher than 69% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Linkit Software Development Kit to 7.3.293.0 or a later version.
  2. Read the advisory on corp.mediatek.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
  4. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
MediaTekEN7516, EN7528, EN7529, EN7561, EN7562, EN7580Linux SDK versions less than TLM-7.3.293.0Not stated
MediaTekLinkit Software Development Kitbefore 7.3.293.07.3.293.0

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.18.8HighNVD
CVSS 3.18.8HighCISA (ADP)

Official description

In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege with User execution privileges needed. User interaction is needed for exploitation. Patch ID: A20220004; Issue ID: OSBNB00140929.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in a Command

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • If possible, ensure that all external commands called from the program are statically created.
  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.

More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Improper Neutralization of Special Elements used in a Command vulnerabilities

Spotted an error? Tell us.