CyberSecBulletin
CVE-2022-33323NVD status: Modified

MELFA SD/SQ Series Controller CR1DA-771 of…: Active Debug Code

CVE-2022-33323 is a high-severity active debug code vulnerability in MELFA SD/SQ Series Controller CR1DA-771 of RV-2SD from Mitsubishi Electric, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected MELFA SD/SQ Series Controller CR1DA-771 of RV-2SD versions: S7x and prior. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.2% chance of exploitation within 30 days, higher than 69% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of MELFA SD/SQ Series Controller CR1DA-771 of RV-2SD you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on mitsubishielectric.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-771 of RV-2SDS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-771 of RV-2SDBS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-721 of RV-3SDS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-721 of RV-3SD-SMS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-721 of RV-3SDCS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-721 of RV-3SDBS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-721 of RV-3SDB-SMS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-731 of RV-3SDBCS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-731 of RV-3SDJS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-731 of RV-3SDJ-SMS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-731 of RV-3SDJCS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-731 of RV-3SDJBS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-731 of RV-3SDJB-SMS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR1DA-731 of RV-3SDJBCS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR2DA-711 of RV-6SDS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR2DA-711 of RV-6SDCS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR2DA-711 of RV-6SDLS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR2DA-711 of RV-6SDLCS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR3D-711M of RV-6SDC-SMS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR3D-711M of RV-6SDLC-SMS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR3D-701M of RV-12SDS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR3D-701 of RV-12SDCS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR3D-701M of RV-12SDLS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR3D-701 of RV-12SDLCS7x and priorNot stated
Mitsubishi ElectricMELFA SD/SQ Series Controller CR2DA-781 of RH-3SDHR3515S7x and priorNot stated

Version data comes from the organisation that assigned the CVE; 35 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
NoneNo data is disclosed.
Integrity
HighData or code can be modified at will.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.5HighCNA (yd.MitsubishiElectric.co.jp)
CVSS 3.17.5HighNVD

Official description

Active Debug Code vulnerability in robot controller of Mitsubishi Electric Corporation industrial robot MELFA SD/SQ Series and MELFA F-Series allows a remote unauthenticated attacker to gain unauthorized access by authentication bypass through an unauthorized telnet login. As for the affected model names, controller types and firmware versions, see the Mitsubishi Electric's advisory which is listed in [References] section.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Active Debug Code

The product is released with debugging code still enabled or active.

How developers prevent this class of flaw

  • Remove debug code before deploying the application.

More Active Debug Code vulnerabilities (CWE-489)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Recent Active Debug Code vulnerabilities

Spotted an error? Tell us.