CyberSecBulletin
CVE-2022-4280NVD status: Modified

Smart Campus System: Incorrect Privilege Assignment

CVE-2022-4280 is a high-severity incorrect privilege assignment vulnerability in Smart Campus System from Dot Tech, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. There is no confirmed exploitation so far. EPSS estimates a 0.8% chance of exploitation within 30 days, higher than 57% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Smart Campus System you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
Dot TechSmart Campus SystemNot specified in the recordNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
NoneNothing can be modified.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.14.3MediumCNA (vuldb.com)
CVSS 3.17.5HighNVD

Official description

A vulnerability, which was classified as problematic, has been found in Dot Tech Smart Campus System. Affected by this issue is some unknown functionality of the file /services/Card/findUser. The manipulation leads to information disclosure. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-214778 is the identifier assigned to this vulnerability.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Incorrect Privilege Assignment

A product incorrectly assigns a privilege to a particular actor, creating an unintended sphere of control for that actor.

How developers prevent this class of flaw

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
  • Run your code using the lowest privileges that are required to accomplish the necessary tasks. If possible, create isolated accounts with limited privileges that are only used for a single task. That way, a successful attack will not immediately give the attacker access to the rest of the software or its environment. For example, database applications rarely need to run as the database administrator, especially in day-to-day operations.

More Incorrect Privilege Assignment vulnerabilities (CWE-266)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Technical write-ups (may include proof of concept)

Recent Incorrect Privilege Assignment vulnerabilities

Spotted an error? Tell us.