CyberSecBulletin
CVE-2022-45936NVD status: Modified

Mendix Email Connector: Improper Access Control

CVE-2022-45936 is a high-severity improper access control vulnerability in Mendix Email Connector from Siemens, with a CVSS 3.1 base score of 8.1 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. Affected Mendix Email Connector versions: All versions < V2.0.0. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.75% chance of exploitation within 30 days, higher than 56% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Mendix Email Connector you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on cert-portal.siemens.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensMendix Email ConnectorAll versions < V2.0.0Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.18.1HighNVD
CVSS 3.18.1HighCISA (ADP)

Official description

A vulnerability has been identified in Mendix Email Connector (All versions < V2.0.0). Affected versions of the module improperly handle access control for some module entities. This could allow authenticated remote attackers to read and manipulate sensitive information.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Access Control

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

How developers prevent this class of flaw

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
  • Compartmentalize the system to have safe areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area. Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.

More Improper Access Control vulnerabilities (CWE-284)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Improper Access Control vulnerabilities

Spotted an error? Tell us.