VibroLine VLX1 HD 5.0: Missing Authentication for Critical Functionality
CVE-2022-50981 is a critical-severity missing authentication for critical functionality vulnerability in VibroLine VLX1 HD 5.0 from Innomic, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected VibroLine VLX1 HD 5.0 versions: 2.1.1340 through 2.1.1387; 2.1.1866. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.58% chance of exploitation within 30 days, which is low compared with other CVEs.
Critical severity: a successful attack would have severe impact.
What to do
- Check which version of VibroLine VLX1 HD 5.0 you run against the affected versions below, and install the vendor's latest release.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Innomic | VibroLine VLX1 HD 5.0 | 2.1.1340 through 2.1.1387; 2.1.1866 | Not stated |
| Innomic | VibroLine VLX2 HD 5.0 | 2.1.1340 through 2.1.1387; 2.1.1866 | Not stated |
| Innomic | VibroLine VLX4 HD 5.0 | 2.1.1340 through 2.1.1387; 2.1.1866 | Not stated |
| Innomic | VibroLine VLX6 HD 5.0 | 2.1.1340 through 2.1.1387; 2.1.1866 | Not stated |
| Innomic | VibroLine VLX8 HD 5.0 | 2.1.1340 through 2.1.1387; 2.1.1866 | Not stated |
| Avibia | AvibiaLine AVLX1 HD 5.0 | 2.1.1340 through 2.1.1387; 2.1.1866 | Not stated |
| Avibia | AvibiaLine AVLX2 HD 5.0 | 2.1.1340 through 2.1.1387; 2.1.1866 | Not stated |
| Avibia | AvibiaLine AVLX4 HD 5.0 | 2.1.1340 through 2.1.1387; 2.1.1866 | Not stated |
| Avibia | AvibiaLine AVLX6 HD 5.0 | 2.1.1340 through 2.1.1387; 2.1.1866 | Not stated |
| Avibia | AvibiaLine AVLX8 HD 5.0 | 2.1.1340 through 2.1.1387; 2.1.1866 | Not stated |
| Innomic | VibroLine VLE1 HD 5.0 | Not specified in the record | Not stated |
| Innomic | VibroLine VLE2 HD 5.0 | Not specified in the record | Not stated |
| Innomic | VibroLine VLE4 HD 5.0 | Not specified in the record | Not stated |
| Innomic | VibroLine VLE6 HD 5.0 | Not specified in the record | Not stated |
| Innomic | VibroLine VLE8 HD 5.0 | Not specified in the record | Not stated |
| Avibia | AvibiaLine AVLE1 HD 5.0 | Not specified in the record | Not stated |
| Avibia | AvibiaLine AVLE2 HD 5.0 | Not specified in the record | Not stated |
| Avibia | AvibiaLine AVLE4 HD 5.0 | Not specified in the record | Not stated |
| Avibia | AvibiaLine AVLE6 HD 5.0 | Not specified in the record | Not stated |
| Avibia | AvibiaLine AVLE8 HD 5.0 | Not specified in the record | Not stated |
| Innomic | VibroLine VLE1 HD 4.0 | Not specified in the record | Not stated |
| Innomic | VibroLine VLE2 HD 4.0 | Not specified in the record | Not stated |
| Innomic | VibroLine VLE4 HD 4.0 | Not specified in the record | Not stated |
| Innomic | VibroLine VLE6 HD 4.0 | Not specified in the record | Not stated |
| Innomic | VibroLine VLE8 HD 4.0 | Not specified in the record | Not stated |
Version data comes from the organisation that assigned the CVE; 5 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (cert.vde.com).
Official description
An unauthenticated remote attacker can gain full access on the affected devices as they are shipped without a password by default and setting one is not enforced.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Missing Authentication for Critical Functionality
The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
How developers prevent this class of flaw
- For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
- Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. For example, consider using libraries with authentication capabilities such as OpenSSL or the ESAPI Authenticator.
- When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to require strong authentication for users who should be allowed to access the data.
More Missing Authentication for Critical Functionality vulnerabilities (CWE-306)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other references
Other vulnerabilities in VibroLine VLX1 HD 5.0
- 8.8 High severity
Recent Missing Authentication for Critical Functionality vulnerabilities
- 9.1 Critical severity
- 9.3 Critical severity
- 9.8 Critical severity
- 9.3 Critical severity
- 9.3 Critical severity
- 9.4 Critical severity
Spotted an error? Tell us.