CyberSecBulletin
CVE-2023-1168NVD status: Modified

Aruba CX 10000 Switch Series, Aruba CX 9300…: Improper Neutralization of Special Elements used in a Command

CVE-2023-1168 is a high-severity improper neutralization of special elements used in a command vulnerability in Aruba CX 10000 Switch Series, Aruba CX 9300 Switch Series, Aruba CX 8400 Switch Series, Aruba CX 8360 Switch Series, Aruba CX 8325 Switch Series, Aruba CX 8320 Switch Series, Aruba CX 6400 Switch Series, Aruba CX 6300 Switch Series, Aruba CX 6200F Switch Series from Hewlett Packard Enterprise, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. Affected Aruba CX 10000 Switch Series, Aruba CX 9300 Switch Series, Aruba CX 8400 Switch Series, Aruba CX 8360 Switch Series, Aruba CX 8325 Switch Series, Aruba CX 8320 Switch Series, Aruba CX 6400 Switch Series, Aruba CX 6300 Switch Series, Aruba CX 6200F Switch Series versions: AOS-CX 10.10.xxxx: 10.10.1020 and below.; AOS-CX 10.09.xxxx: 10.09.1020 and below.; AOS-CX 10.08.xxxx: 10.08.1070 and below., and others listed below. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.14% chance of exploitation within 30 days, higher than 67% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Arubaos-cx to 10.06.0240 or 10.10.1030, whichever matches your release line, or a later version.
  2. Read the advisory on arubanetworks.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
Hewlett Packard EnterpriseAruba CX 10000 Switch Series, Aruba CX 9300 Switch Series, Aruba CX 8400 Switch Series, Aruba CX 8360 Switch Series, Aruba CX 8325 Switch Series, Aruba CX 8320 Switch Series, Aruba CX 6400 Switch Series, Aruba CX 6300 Switch Series, Aruba CX 6200F Switch SeriesAOS-CX 10.10.xxxx: 10.10.1020 and below.; AOS-CX 10.09.xxxx: 10.09.1020 and below.; AOS-CX 10.08.xxxx: 10.08.1070 and below.; AOS-CX 10.06.xxxx: 10.06.0230 and below.Not stated
Hewlett Packard EnterpriseArubaos-cx10.06.0000 up to, but not including, 10.06.0240; 10.08.0000 through 10.08.1070; 10.09.0000 through 10.09.1020; 10.10.0000 up to, but not including, 10.10.103010.06.0240, 10.10.1030

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.2HighCNA (hpe.com)
CVSS 3.18.8HighNVD

Official description

An authenticated remote code execution vulnerability exists in the AOS-CX Network Analytics Engine. Successful exploitation of this vulnerability results in the ability to execute arbitrary code as a privileged user on the underlying operating system, leading to a complete compromise of the switch running AOS-CX.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in a Command

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • If possible, ensure that all external commands called from the program are statically created.
  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.

More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Improper Neutralization of Special Elements used in a Command vulnerabilities

Spotted an error? Tell us.