Medicine Tracker System: Improper Authentication
CVE-2023-1464 is a critical-severity improper authentication vulnerability in Medicine Tracker System from SourceCodester, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Medicine Tracker System versions: 1.0. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.79% chance of exploitation within 30 days, higher than 57% of scored CVEs.
Critical severity: a successful attack would have severe impact.
What to do
- Check which version of Medicine Tracker System you run against the affected versions below, and install the vendor's latest release.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| SourceCodester | Medicine Tracker System | 1.0 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 3.1 | 7.3 | High | CNA (vuldb.com) |
| CVSS 3.1 | 9.8 | Critical | NVD |
| CVSS 2.0 | 7.5 | High | CNA (vuldb.com) |
Official description
A vulnerability, which was classified as critical, was found in SourceCodester Medicine Tracker System 1.0. This affects an unknown part of the file Users.php?f=save_user. The manipulation of the argument firstname/middlename/lastname/username/password leads to improper authentication. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-223311.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Authentication
When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.
How developers prevent this class of flaw
- Use an authentication framework or library such as the OWASP ESAPI Authentication feature.
Timeline
- CVE record published.
- Record last changed materially (score, affected products, status or references).
References
Third-party and government advisories
- vuldb.com/?ctiid.223311Permissions Required, Third Party Advisory, VDB Entry
- vuldb.com/?id.223311Permissions Required, Third Party Advisory, VDB Entry
Other vulnerabilities in Medicine Tracker System
- 8.8 High severity
- 9.8 Critical severity
- 9.8 Critical severity
Recent Improper Authentication vulnerabilities
- 9.8 Critical severity
- 9.8 Critical severity
- 9.8 Critical severity
- 7.5 High severity
- 8.6 High severity
- 9.8 Critical severity
Spotted an error? Tell us.