CyberSecBulletin
CVE-2023-24334NVD status: Analyzed

ac23_firmware: Stack-based Buffer Overflow

CVE-2023-24334 is a high-severity stack-based buffer overflow vulnerability in ac23_firmware from Tenda, with a CVSS 3.1 base score of 8.0 out of 10. It can be exploited from the same local network by an attacker with a low-privileged account, without any action from a user. Affected ac23_firmware versions: 1.0re_v16.03.07.45_cn_tdc01. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.49% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of ac23_firmware you run against the affected versions below, and install the vendor's latest release.

Affected products and versions

VendorProductAffected versionsFixed in
Tendaac23_firmware1.0re_v16.03.07.45_cn_tdc01Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by CISA (ADP).

Official description

A stack overflow vulnerability in Tenda AC23 with firmware version US_AC23V1.0re_V16.03.07.45_cn_TDC01 allows attackers to run arbitrary commands via schedStartTime parameter.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Stack-based Buffer Overflow

The product writes past the end of a buffer that was allocated on the stack.

How developers prevent this class of flaw

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking. D3-SFCV (Stack Frame Canary Validation) from D3FEND discusses canary-based detection in detail.
  • Use an abstraction library to abstract away risky APIs. Not a complete solution.
  • Implement and perform bounds checking on input.

More Stack-based Buffer Overflow vulnerabilities (CWE-121)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Technical write-ups (may include proof of concept)

Other vulnerabilities in ac23_firmware

All ac23_firmware vulnerabilities

Recent Stack-based Buffer Overflow vulnerabilities

Spotted an error? Tell us.