CyberSecBulletin
CVE-2023-29105NVD status: Modified

SIMATIC Cloud Connect 7 CC712: Missing Standardized Error Handling Mechanism

CVE-2023-29105 is a high-severity missing standardized error handling mechanism vulnerability in SIMATIC Cloud Connect 7 CC712 from Siemens, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected SIMATIC Cloud Connect 7 CC712 versions: All versions >= V2.0 < V2.1; All versions < V2.1. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.55% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update 6gk1411-1ac00 Firmware to 2.1 or a later version.
  2. Update 6gk1411-5ac00 Firmware to 2.1 or a later version.
  3. Read the advisory on cert-portal.siemens.com for workarounds and exact fixed builds.
  4. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensSIMATIC Cloud Connect 7 CC712All versions >= V2.0 < V2.1; All versions < V2.1Not stated
SiemensSIMATIC Cloud Connect 7 CC716All versions >= V2.0 < V2.1; All versions < V2.1Not stated
Siemens6gk1411-1ac00 Firmwarebefore 2.12.1
Siemens6gk1411-5ac00 Firmwarebefore 2.12.1

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
NoneNo data is disclosed.
Integrity
NoneNothing can be modified.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.15.9MediumCNA (siemens.com)
CVSS 3.17.5HighNVD

Official description

A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device is vulnerable to a denial of service while parsing a random (non-JSON) MQTT payload. This could allow an attacker who can manipulate the communication between the MQTT broker and the affected device to cause a denial of service (DoS).

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Missing Standardized Error Handling Mechanism

The product does not use a standardized method for handling errors throughout the code.

How developers prevent this class of flaw

  • define a strategy for handling errors of different severities, such as fatal errors versus basic log events. Use or create built-in language features, or an external package, that provides an easy-to-use API and define coding standards for the detection and handling of errors.

More Missing Standardized Error Handling Mechanism vulnerabilities (CWE-544)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in SIMATIC Cloud Connect 7 CC712

All SIMATIC Cloud Connect 7 CC712 vulnerabilities

Spotted an error? Tell us.