SEL-3505: Improper Authentication
CVE-2023-31152 is a high-severity improper authentication vulnerability in SEL-3505 from Schweitzer Engineering Laboratories, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. The record lists versions R150-V2, R149-V4, R148-V7 as the first without the flaw, so updating SEL-3505 to one of those releases or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.36% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update SEL-3505 to R150-V2 or R149-V4 or R148-V7 or R147-V6, whichever matches your release line, or a later version.
- Update SEL-3505-3 to R150-V2 or R149-V4 or R148-V7 or R147-V6, whichever matches your release line, or a later version.
- Update SEL-3530 to R150-V2 or R149-V4 or R148-V7 or R147-V6, whichever matches your release line, or a later version.
- Read the advisory on selinc.com for workarounds and exact fixed builds.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Schweitzer Engineering Laboratories | SEL-3505 | R147-V0 up to, but not including, R150-V2; R147-V0 up to, but not including, R149-V4; R147-V0 up to, but not including, R148-V7; R147-V0 up to, but not including, R147-V6 | R150-V2, R149-V4, R148-V7, R147-V6 |
| Schweitzer Engineering Laboratories | SEL-3505-3 | R147-V0 up to, but not including, R150-V2; R147-V0 up to, but not including, R149-V4; R147-V0 up to, but not including, R148-V7; R147-V0 up to, but not including, R147-V6 | R150-V2, R149-V4, R148-V7, R147-V6 |
| Schweitzer Engineering Laboratories | SEL-3530 | R147-V0 up to, but not including, R150-V2; R147-V0 up to, but not including, R149-V4; R147-V0 up to, but not including, R148-V7; R147-V0 up to, but not including, R147-V6 | R150-V2, R149-V4, R148-V7, R147-V6 |
| Schweitzer Engineering Laboratories | SEL-3530-4 | R147-V0 up to, but not including, R150-V2; R147-V0 up to, but not including, R149-V4; R147-V0 up to, but not including, R148-V7; R147-V0 up to, but not including, R147-V6 | R150-V2, R149-V4, R148-V7, R147-V6 |
| Schweitzer Engineering Laboratories | SEL-3532 | R147-V0 up to, but not including, R150-V2; R147-V0 up to, but not including, R149-V4; R147-V0 up to, but not including, R148-V7; R147-V0 up to, but not including, R147-V6 | R150-V2, R149-V4, R148-V7, R147-V6 |
| Schweitzer Engineering Laboratories | SEL-3555 | R147-V0 up to, but not including, R150-V2; R147-V0 up to, but not including, R149-V4; R147-V0 up to, but not including, R148-V7; R147-V0 up to, but not including, R147-V6 | R150-V2, R149-V4, R148-V7, R147-V6 |
| Schweitzer Engineering Laboratories | SEL-3560S | R147-V0 up to, but not including, R150-V2; R147-V0 up to, but not including, R149-V4; R147-V0 up to, but not including, R148-V7; R147-V0 up to, but not including, R147-V6 | R150-V2, R149-V4, R148-V7, R147-V6 |
| Schweitzer Engineering Laboratories | SEL-3560E | R147-V0 up to, but not including, R150-V2; R147-V0 up to, but not including, R149-V4; R147-V0 up to, but not including, R148-V7; R147-V0 up to, but not including, R147-V6 | R150-V2, R149-V4, R148-V7, R147-V6 |
| Schweitzer Engineering Laboratories | SEL-2241 RTAC module | R147-V0 up to, but not including, R150-V2; R147-V0 up to, but not including, R149-V4; R147-V0 up to, but not including, R148-V7; R147-V0 up to, but not including, R147-V6 | R150-V2, R149-V4, R148-V7, R147-V6 |
| Schweitzer Engineering Laboratories | SEL-3350 | R148-V0 up to, but not including, R150-V2; R148-V0 up to, but not including, R149-V4; R148-V0 up to, but not including, R148-V7 | R150-V2, R149-V4, R148-V7 |
| Selinc | Sel-2241 Rtac Module Firmware | r147-v0 up to, but not including, r150-v2 | r150-v2 |
| Selinc | Sel-3350 Firmware | r148-v0 up to, but not including, r150-v2 | r150-v2 |
| Selinc | Sel-3505 Firmware | r147-v0 up to, but not including, r150-v2 | r150-v2 |
| Selinc | Sel-3505-3 Firmware | r147-v0 up to, but not including, r150-v2 | r150-v2 |
| Selinc | Sel-3530 Firmware | r147-v0 up to, but not including, r150-v2 | r150-v2 |
| Selinc | Sel-3530-4 Firmware | r147-v0 up to, but not including, r150-v2 | r150-v2 |
| Selinc | Sel-3532 Firmware | r147-v0 up to, but not including, r150-v2 | r150-v2 |
| Selinc | Sel-3555 Firmware | r147-v0 up to, but not including, r150-v2 | r150-v2 |
| Selinc | Sel-3560e Firmware | r147-v0 up to, but not including, r150-v2 | r150-v2 |
| Selinc | Sel-3560s Firmware | r147-v0 up to, but not including, r150-v2 | r150-v2 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- LowA basic user account is enough.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 3.1 | 4.0 | Medium | CNA (selinc.com) |
| CVSS 3.1 | 8.8 | High | NVD |
Official description
An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass. See SEL Service Bulletin dated 2022-11-15 for more details.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Authentication
When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.
How developers prevent this class of flaw
- Use an authentication framework or library such as the OWASP ESAPI Authentication feature.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Third-party and government advisories
- nozominetworks.com/blog/Third Party Advisory
Other vulnerabilities in SEL-3505
- 8.8 High severity
- 8.8 High severity
Recent Improper Authentication vulnerabilities
- 7.5 High severity
- 8.8 High severity
- 8.8 High severity
- 9.1 Critical severity
- 7.8 High severity
- 7.5 High severity
Spotted an error? Tell us.