ICR890-4: Improper Access Control
CVE-2023-3271 is a high-severity improper access control vulnerability in ICR890-4 from SICK, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version 2.5.0 as the first without the flaw, so updating ICR890-4 to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.92% chance of exploitation within 30 days, higher than 61% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update ICR890-4 to 2.5.0 or a later version.
- Update Icr890-4 Firmware to 2.5.0 or a later version.
- Read the advisory on sick.com for workarounds and exact fixed builds.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| SICK | ICR890-4 | before 2.5.0 | 2.5.0 |
| Sick | Icr890-4 Firmware | before 2.5.0 | 2.5.0 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- NoneNothing can be modified.
- Availability
- NoneAvailability is not affected.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 3.1 | 8.2 | High | CNA (sick.de) |
| CVSS 3.1 | 7.5 | High | NVD |
Official description
Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to gather information about the system and download data via the REST API by accessing unauthenticated endpoints.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Access Control
The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
How developers prevent this class of flaw
- Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
- Compartmentalize the system to have safe areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area. Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Advisories
Other vulnerabilities in ICR890-4
- 9.4 Critical severity
- 7.5 High severity
- 7.5 High severity
- 7.5 High severity
- 7.5 High severity
Recent Improper Access Control vulnerabilities
- 9.8 Critical severity
- 8.1 High severity
- 8.1 High severity
- 7.3 High severity
- 9.8 Critical severity
- 7.5 High severity
Spotted an error? Tell us.