CyberSecBulletin
CVE-2023-39226NVD status: Modified

InfraSuite Device Master: Exposed Dangerous Method or Function

CVE-2023-39226 is a critical-severity exposed dangerous method or function vulnerability in InfraSuite Device Master from Delta Electronics, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected InfraSuite Device Master versions: 1.0.7 and earlier. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.18% chance of exploitation within 30 days, higher than 68% of scored CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of InfraSuite Device Master you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
Delta ElectronicsInfraSuite Device Master1.0.7 and earlierNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.19.8CriticalCNA (hq.dhs.gov)
CVSS 3.19.8CriticalNVD

Official description

In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Exposed Dangerous Method or Function

The product provides an Applications Programming Interface (API) or similar interface for interaction with external actors, but the interface includes a dangerous method or function that is not properly restricted.

How developers prevent this class of flaw

  • If you must expose a method, make sure to perform input validation on all arguments, limit access to authorized parties, and protect against all possible vulnerabilities.
  • Identify all exposed functionality. Explicitly list all functionality that must be exposed to some user or set of users. Identify which functionality may be: accessible to all users restricted to a small set of privileged users prevented from being directly accessible at all Ensure that the implemented code follows these expectations. This includes setting the appropriate access modifiers where applicable (public, private, protected, etc.) or not marking ActiveX controls safe-for-scripting.

More Exposed Dangerous Method or Function vulnerabilities (CWE-749)

Timeline

  1. CVE record published.
  2. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Other vulnerabilities in InfraSuite Device Master

All InfraSuite Device Master vulnerabilities

Recent Exposed Dangerous Method or Function vulnerabilities

Spotted an error? Tell us.