CBIS,NCS: Improper Neutralization of Special Elements used in a Command
CVE-2023-49565 is a high-severity improper neutralization of special elements used in a command vulnerability in CBIS,NCS from Nokia, with a CVSS 3.1 base score of 8.4 out of 10. It can be exploited from the same local network by an attacker with administrator privileges, without any action from a user. Affected CBIS,NCS versions: CBIS 22, NCS 22.12, NCS 23.10. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.76% chance of exploitation within 30 days, higher than 56% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of CBIS,NCS you run against the affected versions below, and install the vendor's latest release.
- Read the advisory on nokia.com for workarounds and exact fixed builds.
Affected products and versions
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- AdjacentThe attacker must be on the same local network segment.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- HighAdministrator-level access is required first.
- User interaction
- NoneNo action by a victim is required.
- Scope
- ChangedThe attack can reach beyond the vulnerable component into other systems.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H. Scored by CISA (ADP).
Official description
The cbis_manager Podman container is vulnerable to remote command execution via the /api/plugins endpoint. Improper sanitization of the HTTP Headers X-FILENAME, X-PAGE, and X-FIELD allows for command injection. These headers are directly utilized within the subprocess.Popen Python function without adequate validation, enabling a remote attacker to execute arbitrary commands on the underlying system by crafting malicious header values within an HTTP request to the affected endpoint. The web service executes with root privileges within the container environment, the demonstrated remote code execution permits an attacker to acquire elevated privileges for the command execution. Restricting access to the management network with an external firewall can partially mitigate this risk.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other vulnerabilities in CBIS,NCS
- 8.8 High severity
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 9.8 Critical severity
- 8.8 High severity
- 9.8 Critical severity
- 8.8 High severity
- 8.8 High severity
- 9.8 Critical severity
Spotted an error? Tell us.