HP PC BIOS: Observable Discrepancy

CVE-2023-5410 is a high-severity observable discrepancy vulnerability in HP PC BIOS from HP, with a CVSS 3.1 base score of 8.2 out of 10. It can be exploited with local access to the system by an attacker with administrator privileges, without any action from a user. Affected HP PC BIOS versions: See HP Security Bulletin reference for affected versions. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.18% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of HP PC BIOS you run against the affected versions below, and install the vendor's latest release.

Affected products and versions

VendorProductAffected versionsFixed in
HPHP PC BIOSSee HP Security Bulletin reference for affected versionsNot stated
HPbusiness_notebook_pcs1.03.01 through 1.15.01Not stated
HPbusiness_desktop_pcs2.12.02 through 2.12.03Not stated
HPworkstations2.04.02Not stated
HPthin_client1.09.01 through 1.15.01Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
HighAdministrator-level access is required first.
User interaction
NoneNo action by a victim is required.
Scope
ChangedThe attack can reach beyond the vulnerable component into other systems.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H. Scored by CISA (ADP).

Official description

A potential security vulnerability has been reported in the system BIOS of certain HP PC products, which might allow memory tampering. HP is releasing mitigation for the potential vulnerability.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Observable Discrepancy

The product behaves differently or sends different responses under different circumstances in a way that is observable to an unauthorized actor.

How developers prevent this class of flaw

  • Compartmentalize the system to have safe areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area. Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.

More Observable Discrepancy vulnerabilities (CWE-203)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in HP PC BIOS

All HP PC BIOS vulnerabilities

Recent Observable Discrepancy vulnerabilities

Spotted an error? Tell us.