MİA-MED: Exposure of Sensitive Information Due to Incompatible Policies
CVE-2023-6517 is a high-severity exposure of sensitive information due to incompatible policies vulnerability in MİA-MED from Mia Technology, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version 1.0.7 as the first without the flaw, so updating MİA-MED to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.47% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update MİA-MED to 1.0.7 or a later version.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Mia Technology | MİA-MED | before 1.0.7 | 1.0.7 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- NoneNothing can be modified.
- Availability
- NoneAvailability is not affected.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N. Scored by CNA (usom.gov.tr).
Official description
Exposure of Sensitive Information Due to Incompatible Policies vulnerability in Mia Technology Inc. MİA-MED allows Collect Data as Provided by Users. This issue affects MİA-MED: before 1.0.7.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Exposure of Sensitive Information Due to Incompatible Policies
The product's intended functionality exposes information to certain actors in accordance with the developer's security policy, but this information is regarded as sensitive according to the intended security policies of other stakeholders such as the product's administrator, users, or others whose information is being processed.
How developers prevent this class of flaw
- When handling information, the developer must consider whether the information is regarded as sensitive by different stakeholders, such as users or administrators. Each stakeholder effectively has its own intended security policy that the product is expected to uphold. When a developer does not treat that information as sensitive, this can introduce a vulnerability that violates the expectations of the product's users.
More Exposure of Sensitive Information Due to Incompatible Policies vulnerabilities (CWE-213)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Third-party and government advisories
- usom.gov.tr/bildirim/tr-24-0087Third Party Advisory
Other references
Other vulnerabilities in MİA-MED
- 7.5 High severity
- 7.5 High severity
- 8.8 High severity
- 9.8 Critical severity
Recent Exposure of Sensitive Information Due to Incompatible Policies vulnerabilities
- 7.5 High severity
Spotted an error? Tell us.