i9: NULL Pointer Dereference
CVE-2024-11650 is a high-severity NULL pointer dereference vulnerability in i9 from Tenda, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected i9 versions: 1.0.0.8(3828). The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.27% chance of exploitation within 30 days, higher than 70% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of i9 you run against the affected versions below, and install the vendor's latest release.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Tenda | i9 | 1.0.0.8(3828) | Not stated |
| Tenda | i9_firmware | 1.0.0.8 (3828) | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- NoneNo data is disclosed.
- Integrity
- NoneNothing can be modified.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 7.1 | High | CNA (vuldb.com) |
| CVSS 3.1 | 6.5 | Medium | CNA (vuldb.com) |
| CVSS 3.1 | 7.5 | High | NVD |
| CVSS 2.0 | 6.8 | Medium | CNA (vuldb.com) |
Official description
A vulnerability was found in Tenda i9 1.0.0.8(3828) and classified as critical. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: NULL Pointer Dereference
The product dereferences a pointer that it expects to be valid but is NULL.
How developers prevent this class of flaw
- For any pointers that could have been modified or provided from a function that can return NULL, check the pointer for NULL before use. When working with a multithreaded or otherwise asynchronous environment, ensure that proper locking APIs are used to lock before the check, and unlock when it has finished.
- Select a programming language that is not susceptible to these issues.
- Check the results of all functions that return a value and verify that the value is non-null before acting upon it.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Third-party and government advisories
- vuldb.com/?submit.446592Third Party Advisory, VDB Entry
Technical write-ups (may include proof of concept)
- github.com/xiaobor123/tenda-vul-i9Exploit, Third Party Advisory
Other references
- vuldb.com/?ctiid.285971Permissions Required, VDB Entry
- vuldb.com/?id.285971Permissions Required, VDB Entry
- tenda.com.cn/Product
Other vulnerabilities in i9
- 9.8 Critical severity
- 9.8 Critical severity
Recent NULL Pointer Dereference vulnerabilities
- 7.5 High severity
- 7.5 High severity
- 8.7 High severity
- 7.5 High severity
- 7.5 High severity
- 7.8 High severity
Spotted an error? Tell us.