Arena®: Out-of-bounds Read
CVE-2024-12130 is a high-severity out-of-bounds read vulnerability in Arena® from Rockwell Automation, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected Arena® versions: All versions 16.20.03 and prior. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.3% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of Arena® you run against the affected versions below, and install the vendor's latest release.
- Read the advisory on rockwellautomation.com for workarounds and exact fixed builds.
- Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Rockwell Automation | Arena® | All versions 16.20.03 and prior | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- LocalThe attacker needs local access or must trick a user into running something.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- RequiredA user must take an action such as opening a file or link.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 8.5 | High | CNA (rockwellautomation.com) |
| CVSS 3.1 | 7.8 | High | NVD |
Official description
An “out of bounds read” code execution vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to craft a DOE file and force the software to read beyond the boundaries of an allocated memory. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Out-of-bounds Read
The product reads data past the end, or before the beginning, of the intended buffer.
How developers prevent this class of flaw
- Use a language that provides appropriate memory abstractions.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Other vulnerabilities in Arena®
- 7.5 High severity