CyberSecBulletin
CVE-2024-1713NVD status: Analyzed

Plv8: Improper Check for Unusual or Exceptional Conditions

CVE-2024-1713 is a high-severity improper check for unusual or exceptional conditions vulnerability in Plv8, with a CVSS 3.1 base score of 7.2 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. Affected Plv8 versions: 3.2.1. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.55% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Plv8 you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on github.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
Plv8Plv83.2.1Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
HighAdministrator-level access is required first.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.2HighCNA (google.com)
CVSS 3.17.2HighNVD

Official description

A user who can create objects in a database with plv8 3.2.1 installed is able to cause deferred triggers to execute as the Superuser during autovacuum.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Check for Unusual or Exceptional Conditions

The product does not check or incorrectly checks for unusual or exceptional conditions that are not expected to occur frequently during day to day operation of the product.

How developers prevent this class of flaw

  • Use a language that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. Choose languages with features such as exception handling that force the programmer to anticipate unusual conditions that may generate exceptions. Custom exceptions may need to be developed to handle unusual business-logic conditions. Be careful not to pass sensitive exceptions back to the user (CWE-209, CWE-248).
  • Check the results of all functions that return a value and verify that the value is expected.
  • If using exception handling, catch and throw specific exceptions instead of overly-general exceptions (CWE-396, CWE-397). Catch and handle exceptions as locally as possible so that exceptions do not propagate too far up the call stack (CWE-705). Avoid unchecked or uncaught exceptions where feasible (CWE-248).

More Improper Check for Unusual or Exceptional Conditions vulnerabilities (CWE-754)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Improper Check for Unusual or Exceptional Conditions vulnerabilities

Spotted an error? Tell us.