CyberSecBulletin
CVE-2024-22106NVD status: Modified

windriver: Improper Privilege Management

CVE-2024-22106 is a high-severity improper privilege management vulnerability in windriver from Jungo, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an attacker with a low-privileged account, without any action from a user. The record lists version 12.5.1 as the first without the flaw, so updating windriver to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.18% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update windriver to 12.5.1 or a later version.
  2. Read the advisory on mitsubishielectric.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
Jungowindriverbefore 12.5.112.5.1
Mitsubishi ElectricCpu Module Logging Configuration ToolNot specified in the recordNot stated
Mitsubishi ElectricCw ConfiguratorNot specified in the recordNot stated
Mitsubishi ElectricData TransferNot specified in the recordNot stated
Mitsubishi ElectricData Transfer ClassicNot specified in the recordNot stated
Mitsubishi ElectricEzsocketNot specified in the recordNot stated
Mitsubishi ElectricFr Configurator Sw3Not specified in the recordNot stated
Mitsubishi ElectricFr Configurator2Not specified in the recordNot stated
Mitsubishi ElectricGenesis64Not specified in the recordNot stated
Mitsubishi ElectricGt Got1000Not specified in the recordNot stated
Mitsubishi ElectricGt Got2000Not specified in the recordNot stated
Mitsubishi ElectricGt Softgot1000Not specified in the recordNot stated
Mitsubishi ElectricGt Softgot2000Not specified in the recordNot stated
Mitsubishi ElectricGx DeveloperNot specified in the recordNot stated
Mitsubishi ElectricGx LogviewerNot specified in the recordNot stated
Mitsubishi ElectricGx Works2Not specified in the recordNot stated
Mitsubishi ElectricGx Works3Not specified in the recordNot stated
Mitsubishi ElectricIq WorksNot specified in the recordNot stated
Mitsubishi ElectricMi ConfiguratorNot specified in the recordNot stated
Mitsubishi ElectricMr ConfiguratorNot specified in the recordNot stated
Mitsubishi ElectricMr Configurator2Not specified in the recordNot stated
Mitsubishi ElectricMx ComponentNot specified in the recordNot stated
Mitsubishi ElectricMx Opc Server Da/uaNot specified in the recordNot stated
Mitsubishi ElectricNumerical Control Device CommunicationNot specified in the recordNot stated
Mitsubishi ElectricPx Developer/monitor ToolNot specified in the recordNot stated

Version data comes from the organisation that assigned the CVE; 10 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.8HighNVD
CVSS 3.18.8HighCISA (ADP)

Official description

Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges, execute arbitrary code, or cause a Denial of Service (DoS).

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Privilege Management

The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.

How developers prevent this class of flaw

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
  • Follow the principle of least privilege when assigning access rights to entities in a software system.
  • Consider following the principle of separation of privilege. Require multiple conditions to be met before permitting access to a system resource.

More Improper Privilege Management vulnerabilities (CWE-269)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Patches and release notes

Third-party and government advisories

Recent Improper Privilege Management vulnerabilities

Spotted an error? Tell us.