SIMATIC RTLS Locating Manager: Download of Code Without Integrity Check

CVE-2024-30206 is a high-severity download of code without integrity check vulnerability in SIMATIC RTLS Locating Manager from Siemens, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited from the same local network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. The record lists versions V3.0.1.1, 3.0.1.1 as the first without the flaw, so updating SIMATIC RTLS Locating Manager to one of those releases or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.31% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update SIMATIC RTLS Locating Manager to V3.0.1.1 or 3.0.1.1, whichever matches your release line, or a later version.
  2. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensSIMATIC RTLS Locating Managerbefore V3.0.1.1; before 3.0.1.1V3.0.1.1, 3.0.1.1

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
ChangedThe attack can reach beyond the vulnerable component into other systems.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H. Scored by CNA (siemens.com).

Scoring systemScoreSeverityScored by
CVSS 4.08.8HighCNA (siemens.com)
CVSS 3.18.8HighCNA (siemens.com)

Official description

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Clients do not properly check the integrity of update files. This could allow an unauthenticated remote attacker to alter update files in transit and trick an authorized user into installing malicious code. A successful exploit requires the attacker to be able to modify the communication between server and client on the network.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Download of Code Without Integrity Check

The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code.

How developers prevent this class of flaw

  • Perform proper forward and reverse DNS lookups to detect DNS spoofing.
  • Encrypt the code with a reliable encryption scheme before transmitting.
  • Run your code using the lowest privileges that are required to accomplish the necessary tasks. If possible, create isolated accounts with limited privileges that are only used for a single task. That way, a successful attack will not immediately give the attacker access to the rest of the software or its environment. For example, database applications rarely need to run as the database administrator, especially in day-to-day operations.

More Download of Code Without Integrity Check vulnerabilities (CWE-494)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).