o3v2: Improper Neutralization of Special Elements used in a Command
CVE-2024-34338 is a high-severity improper neutralization of special elements used in a command vulnerability in o3v2 from Tenda, with a CVSS 3.1 base score of 7.2 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. Affected o3v2 versions: 1.0.0.10; 1.0.0.12. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 2.85% chance of exploitation within 30 days, higher than 87% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of o3v2 you run against the affected versions below, and install the vendor's latest release.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Tenda | o3v2 | 1.0.0.10; 1.0.0.12 | Not stated |
| Tenda | O3 Firmware | 1.0.0.10; 1.0.0.12 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- HighAdministrator-level access is required first.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Scored by CISA (ADP).
Official description
Tenda O3V2 with firmware versions V1.0.0.10 and V1.0.0.12 was discovered to contain a Blind Command Injection via dest parameter in /goform/getTraceroute. This vulnerability allows attackers to execute arbitrary commands with root privileges. Authentication is required to exploit this vulnerability.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Technical write-ups (may include proof of concept)
- exzettabyte.me/blind-command-injection-in-tenda-o3v2Exploit, Third Party Advisory
Other vulnerabilities in o3v2
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 8.0 High severity
- 9.8 Critical severity
- 7.2 High severity
- 7.8 High severity
- 7.8 High severity
- 7.5 High severity
Spotted an error? Tell us.