ex3700_ac750: Improper Neutralization of Special Elements used in a Command
CVE-2024-35522 is a high-severity improper neutralization of special elements used in a command vulnerability in ex3700_ac750 from NETGEAR, with a CVSS 3.1 base score of 7.2 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. The record lists version 1.0.0.98 as the first without the flaw, so updating ex3700_ac750 to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 1.87% chance of exploitation within 30 days, higher than 80% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update ex3700_ac750 to 1.0.0.98 or a later version.
- Update Ex3700 Firmware to 1.0.0.98 or a later version.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| NETGEAR | ex3700_ac750 | before 1.0.0.98 | 1.0.0.98 |
| NETGEAR | Ex3700 Firmware | before 1.0.0.98 | 1.0.0.98 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- HighAdministrator-level access is required first.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 3.1 | 8.4 | High | CNA (mitre.org) |
| CVSS 3.1 | 7.2 | High | NVD |
Official description
Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Technical write-ups (may include proof of concept)
- github.com/consrc/cves/blob/main/CVE-2024-35522.mdExploit, Third Party Advisory
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 8.8 High severity
- 7.3 High severity
- 7.8 High severity
- 8.4 High severity
- 8.8 High severity
- 8.8 High severity
Spotted an error? Tell us.