CyberSecBulletin
CVE-2024-37569NVD status: Modified

6869i_firmware: Improper Neutralization of Special Elements used in a Command

CVE-2024-37569 is a high-severity improper neutralization of special elements used in a command vulnerability in 6869i_firmware from Mitel, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. Affected 6869i_firmware versions: 4.5.0.41; 5.0.0.1018. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 3.2% chance of exploitation within 30 days, higher than 88% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of 6869i_firmware you run against the affected versions below, and install the vendor's latest release.

Affected products and versions

VendorProductAffected versionsFixed in
Mitel6869i_firmware4.5.0.41; 5.0.0.1018Not stated
Mitel6869i Sip Firmware4.5.0.41 and earlier; 5.0.0.0 through 5.0.0.1018Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.18.8HighNVD
CVSS 3.18.3HighCISA (ADP)

Official description

An issue was discovered on Mitel 6869i through 4.5.0.41 and 5.x through 5.0.0.1018 devices. A command injection vulnerability exists in the hostname parameter taken in by the provis.html endpoint. The provis.html endpoint performs no sanitization on the hostname parameter (sent by an authenticated user), which is subsequently written to disk. During boot, the hostname parameter is executed as part of a series of shell commands. Attackers can achieve remote code execution in the root context by placing shell metacharacters in the hostname parameter.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in a Command

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • If possible, ensure that all external commands called from the program are statically created.
  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.

More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Technical write-ups (may include proof of concept)

Recent Improper Neutralization of Special Elements used in a Command vulnerabilities

Spotted an error? Tell us.