CyberSecBulletin
CVE-2024-41985NVD status: Analyzed

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions…

CVE-2024-41985 is a high-severity vulnerability in SmartClient modules Opcenter QL Home (SC) from Siemens, with a CVSS 3.1 base score of 7.3 out of 10. It can be exploited from the same local network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. The record lists version V2506 as the first without the flaw, so updating SmartClient modules Opcenter QL Home (SC) to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.2% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update SmartClient modules Opcenter QL Home (SC) to V2506 or a later version.
  2. Update SOA Audit to V2506 or a later version.
  3. Update SOA Cockpit to V2506 or a later version.
  4. Read the advisory on cert-portal.siemens.com for workarounds and exact fixed builds.
  5. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensSmartClient modules Opcenter QL Home (SC)V13.2 up to, but not including, V2506V2506
SiemensSOA AuditV13.2 up to, but not including, V2506V2506
SiemensSOA CockpitV13.2 up to, but not including, V2506V2506
SiemensOpcenter Quality13.2Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.02.1LowCNA (siemens.com)
CVSS 3.12.6LowCNA (siemens.com)
CVSS 3.17.3HighNVD

Official description

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not expire the session without logout. This could allow an attacker to get unauthorized access if the session is left idle.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in SmartClient modules Opcenter QL Home (SC)

All SmartClient modules Opcenter QL Home (SC) vulnerabilities

Spotted an error? Tell us.