di-7003g_firmware: Improper Neutralization of Special Elements used in a Command
CVE-2024-44334 is a high-severity improper neutralization of special elements used in a command vulnerability in di-7003g_firmware from D-Link, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited from the same local network by an unauthenticated attacker, without any action from a user. Affected di-7003g_firmware versions: 19.12.24a1. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 31.8% chance of exploitation within 30 days, which is in the top 1.68% of all scored CVEs.
EPSS places it among the vulnerabilities most likely to be exploited soon.
What to do
- Check which version of di-7003g_firmware you run against the affected versions below, and install the vendor's latest release.
- Read the advisory on dlink.com for workarounds and exact fixed builds.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| D-Link | di-7003g_firmware | 19.12.24a1 | Not stated |
| D-Link | di-7003gv2_firmware | 24.04.18d1 | Not stated |
| D-Link | di-7100g\+v2_firmware | 24.04.18d1 | Not stated |
| D-Link | di-7100gv2_firmware | 24.04.18d1 | Not stated |
| D-Link | di-7200gv2_firmware | 24.04.18e1 | Not stated |
| D-Link | di-7200g\+v2_firmware | 24.04.18d1 | Not stated |
| D-Link | di-7400g\+v2_firmware | 24.04.18d1 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- AdjacentThe attacker must be on the same local network segment.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CISA (ADP).
Official description
D-Link DI-7003GV2 v24.04.18D1, DI-7100G+V2 v24.04.18D1, DI-7100GV2 v24.04.18D1, DI-7200GV2 v24.04.18E1, DI-7300G+V2 v24.04.18D1, and DI-7400G+V2 v24.04.18D1 are vulnerable to Remote Command Execution due to insufficient parameter filtering in the CGI handling function of upgrade_filter.asp.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Advisories
Other references
Other vulnerabilities in di-7003g_firmware
- 7.5 High severity
- 7.5 High severity
- 7.5 High severity
- 7.5 High severity
- 7.5 High severity
- 8.8 High severity
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 8.1 High severity
- 7.8 High severity
- 8.8 High severity
- 8.8 High severity
- 9.8 Critical severity
- 7.2 High severity
Spotted an error? Tell us.