CyberSecBulletin
CVE-2024-45367NVD status: Deferred

ONS-S8 Spectra Aggregation Switch: Weak Authentication

CVE-2024-45367 is a critical-severity weak authentication vulnerability in ONS-S8 Spectra Aggregation Switch from Optigo Networks, with a CVSS 3.1 base score of 9.1 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected ONS-S8 Spectra Aggregation Switch versions: 1.3.7 and earlier. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.51% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of ONS-S8 Spectra Aggregation Switch you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
Optigo NetworksONS-S8 Spectra Aggregation Switch1.3.7 and earlierNot stated
Optigoons-s8_firmware1.3.7 and earlierNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N. Scored by CNA (hq.dhs.gov).

Scoring systemScoreSeverityScored by
CVSS 4.09.3CriticalCNA (hq.dhs.gov)
CVSS 3.19.1CriticalCNA (hq.dhs.gov)

Official description

The web server for ONS-S8 - Spectra Aggregation Switch includes an incomplete authentication process, which can lead to an attacker authenticating without a password.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Weak Authentication

The product uses an authentication mechanism to restrict access to specific users or identities, but the mechanism does not sufficiently prove that the claimed identity is correct.

More Weak Authentication vulnerabilities (CWE-1390)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in ONS-S8 Spectra Aggregation Switch

All ONS-S8 Spectra Aggregation Switch vulnerabilities

Recent Weak Authentication vulnerabilities

Spotted an error? Tell us.