A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo…
CVE-2024-45386 is a high-severity vulnerability in SIMATIC PCS neo V4.0 from Siemens, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected SIMATIC PCS neo V4.0 versions: all versions. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.56% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update SIMATIC PCS neo V4.1 to V4.1 Update 2 or a later version.
- Update SIMATIC PCS neo V5.0 to V5.0 Update 1 or a later version.
- Update SIMOCODE ES V19 to V19 Update 1 or a later version.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
- Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Siemens | SIMATIC PCS neo V4.0 | all versions | Not stated |
| Siemens | SIMATIC PCS neo V4.1 | before V4.1 Update 2 | V4.1 Update 2 |
| Siemens | SIMATIC PCS neo V5.0 | before V5.0 Update 1 | V5.0 Update 1 |
| Siemens | SIMOCODE ES V19 | before V19 Update 1 | V19 Update 1 |
| Siemens | SIRIUS Safety ES V19 (TIA Portal) | before V19 Update 1 | V19 Update 1 |
| Siemens | SIRIUS Soft Starter ES V19 (TIA Portal) | before V19 Update 1 | V19 Update 1 |
| Siemens | TIA Administrator | before V3.0.4 | V3.0.4 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- RequiredA user must take an action such as opening a file or link.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by CNA (siemens.com).
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 8.7 | High | CNA (siemens.com) |
| CVSS 3.1 | 8.8 | High | CNA (siemens.com) |
Official description
A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SIMOCODE ES V19 (All versions < V19 Update 1), SIRIUS Safety ES V19 (TIA Portal) (All versions < V19 Update 1), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions < V19 Update 1), TIA Administrator (All versions < V3.0.4). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other references
Other vulnerabilities in SIMATIC PCS neo V4.0
- 9.8 Critical severity
- 9.8 Critical severity
- 7.8 High severity
- 7.5 High severity
Spotted an error? Tell us.