CVE-2024-46891NVD status: Analyzed

SINEC INS: Uncontrolled Resource Consumption

CVE-2024-46891 is a high-severity uncontrolled resource consumption vulnerability in SINEC INS from Siemens, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version V1.0 SP2 Update 3 as the first without the flaw, so updating SINEC INS to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.52% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update SINEC INS to V1.0 SP2 Update 3 or a later version.
  2. Update sinec_ins to V1.0_SP2_Update 3 or a later version.
  3. Read the advisory on cert-portal.siemens.com for workarounds and exact fixed builds.
  4. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensSINEC INSbefore V1.0 SP2 Update 3V1.0 SP2 Update 3
Seimenssinec_insbefore V1.0_SP2_Update 3V1.0_SP2_Update 3

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
NoneNo data is disclosed.
Integrity
NoneNothing can be modified.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.06.9MediumCNA (siemens.com)
CVSS 3.15.3MediumCNA (siemens.com)
CVSS 3.17.5HighNVD

Official description

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Uncontrolled Resource Consumption

The product does not properly control the allocation and maintenance of a limited resource.

How developers prevent this class of flaw

  • Ensure that protocols have specific limits of scale placed on them.
  • Ensure that all failures in resource allocation place the system into a safe posture.

More Uncontrolled Resource Consumption vulnerabilities (CWE-400)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in SINEC INS

All SINEC INS vulnerabilities

Recent Uncontrolled Resource Consumption vulnerabilities

Spotted an error? Tell us.