Siem: Improper Neutralization of Special Elements used in a Command
CVE-2024-56086 is a high-severity improper neutralization of special elements used in a command vulnerability in Siem from Logpoint, with a CVSS 3.1 base score of 7.1 out of 10. It can be exploited from the same local network by an attacker with a low-privileged account, without any action from a user. The record lists version 7.5.0 as the first without the flaw, so updating Siem to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.41% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update Siem to 7.5.0 or a later version.
- Read the advisory on servicedesk.logpoint.com for workarounds and exact fixed builds.
Affected products and versions
Version data comes from NVD's product matching. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- AdjacentThe attacker must be on the same local network segment.
- Attack complexity
- HighSuccess depends on conditions outside the attacker's control.
- Privileges required
- LowA basic user account is enough.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by CISA (ADP).
Official description
An issue was discovered in Logpoint before 7.5.0. Authenticated users can inject payloads in Report Templates. These are executed when the backup process is initiated, leading to Remote Code Execution.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other vulnerabilities in Siem
- 8.8 High severity
- 7.5 High severity
- 7.5 High severity
- 7.5 High severity
- 9.6 Critical severity
- 8.8 High severity
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 7.1 High severity
- 9.8 Critical severity
- 8.4 High severity
- 7.2 High severity
- 7.2 High severity
- 8.8 High severity
Spotted an error? Tell us.