CyberSecBulletin
CVE-2024-7517NVD status: Analyzed

Fabric OS: Improper Neutralization of Special Elements used in an OS Command

CVE-2024-7517 is a high-severity improper neutralization of special elements used in an OS command vulnerability in Fabric OS from Brocade, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an attacker with a low-privileged account, without any action from a user. The record lists versions 9.2.0c, 9.2.1a as the first without the flaw, so updating Fabric OS to one of those releases or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.62% chance of exploitation within 30 days, higher than 50% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Fabric OS to 9.2.0c or 9.2.1a, whichever matches your release line, or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
BrocadeFabric OSbefore 9.2.0c; 9.2.1 up to, but not including, 9.2.1a9.2.0c, 9.2.1a
BroadcomFabric Operating System9.2.0c and earlier; 9.2.1 through 9.2.1aNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.08.5HighCNA (brocade.com)
CVSS 3.17.8HighNVD

Official description

A command injection vulnerability in Brocade Fabric OS before 9.2.0c, and 9.2.1 through 9.2.1a on IP extension platforms could allow a local authenticated attacker to perform a privileged escalation via crafted use of the portcfg command. This specific exploitation is only possible on IP Extension platforms: Brocade 7810, Brocade 7840, Brocade 7850 and on Brocade X6 or X7 directors with an SX-6 Extension blade installed. The attacker must be logged into the switch via SSH or serial console to conduct the attack.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in an OS Command

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • For any data that will be used to generate a command to be executed, keep as much of that data out of external control as possible. For example, in web applications, this may require storing the data locally in the session's state instead of sending it out to the client in a hidden form field.
  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

More Improper Neutralization of Special Elements used in an OS Command vulnerabilities (CWE-78)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in Fabric OS

All Fabric OS vulnerabilities

Recent Improper Neutralization of Special Elements used in an OS Command vulnerabilities

Spotted an error? Tell us.