CyberSecBulletin
CVE-2024-7899NVD status: Analyzed

InnoCMS: Improper Control of Generation of Code

CVE-2024-7899 is a high-severity improper control of generation of code vulnerability in InnoCMS, with a CVSS 3.1 base score of 7.2 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. Affected InnoCMS versions: 0.3.1. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.71% chance of exploitation within 30 days, higher than 54% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of InnoCMS you run against the affected versions below, and install the vendor's latest release.

Affected products and versions

VendorProductAffected versionsFixed in
InnoCMSInnoCMS0.3.1Not stated
Innovative CMSinnovative_cms0.3.1Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
HighAdministrator-level access is required first.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.05.1MediumCNA (vuldb.com)
CVSS 3.14.7MediumCNA (vuldb.com)
CVSS 3.17.2HighNVD
CVSS 2.05.8MediumCNA (vuldb.com)

Official description

A vulnerability, which was classified as critical, has been found in InnoCMS 0.3.1. This issue affects some unknown processing of the file /panel/pages/1/edit of the component Backend. The manipulation leads to code injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Control of Generation of Code

The product constructs all or part of a code segment using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the syntax or behavior of the intended code segment.

How developers prevent this class of flaw

  • Refactor your program so that you do not have to dynamically generate code.
  • Run your code in a jail or similar sandbox environment that enforces strict boundaries between the process and the operating system. This may effectively restrict which code can be executed by your product. Examples include the Unix chroot jail and AppArmor. In general, managed code may provide some protection. This may not be a feasible solution, and it only limits the impact to the operating system; the rest of your application may still be subject to compromise. Be careful to avoid CWE-243 and other weaknesses related to jails.
  • Use dynamic tools and techniques that interact with the product using large test suites with many diverse inputs, such as fuzz testing (fuzzing), robustness testing, and fault injection. The product's operation may slow down, but it should not become unstable, crash, or generate incorrect results.

More Improper Control of Generation of Code vulnerabilities (CWE-94)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Technical write-ups (may include proof of concept)

Recent Improper Control of Generation of Code vulnerabilities

Spotted an error? Tell us.