Life2000 Ventilation System: Improper Restriction of Excessive Authentication Attempts
CVE-2024-9832 is a critical-severity improper restriction of excessive authentication attempts vulnerability in Life2000 Ventilation System from Baxter, with a CVSS 3.1 base score of 9.3 out of 10. It can be exploited with local access to the system by an unauthenticated attacker, without any action from a user. Affected Life2000 Ventilation System versions: 06.08.00.00 and prior. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.18% chance of exploitation within 30 days, which is low compared with other CVEs.
Critical severity: a successful attack would have severe impact.
What to do
- Check which version of Life2000 Ventilation System you run against the affected versions below, and install the vendor's latest release.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Baxter | Life2000 Ventilation System | 06.08.00.00 and prior | Not stated |
| Baxter | life2000_ventilator_firmware | 06.08.00.00 and earlier | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- LocalThe attacker needs local access or must trick a user into running something.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- ChangedThe attack can reach beyond the vulnerable component into other systems.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H. Scored by CNA (baxter.com).
Official description
There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to device settings that could disrupt the function of the device and/or result in unauthorized information disclosure.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Restriction of Excessive Authentication Attempts
The product does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame.
How developers prevent this class of flaw
- Common protection mechanisms include: Disconnecting the user after a small number of failed attempts Implementing a timeout Locking out a targeted account Requiring a computational task on the user's part.
- Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. Consider using libraries with authentication capabilities such as OpenSSL or the ESAPI Authenticator.
More Improper Restriction of Excessive Authentication Attempts vulnerabilities (CWE-307)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other references
Other vulnerabilities in Life2000 Ventilation System
- 9.3 Critical severity
- 9.3 Critical severity
- 9.3 Critical severity
- 9.3 Critical severity
- 10.0 Critical severity
- 10.0 Critical severity
Recent Improper Restriction of Excessive Authentication Attempts vulnerabilities
- 9.8 Critical severity
- 9.1 Critical severity
- 8.8 High severity
- 9.8 Critical severity
- 9.8 Critical severity
- 9.8 Critical severity
Spotted an error? Tell us.