Security Gateway: Weak Password Recovery Mechanism for Forgotten Password
CVE-2025-10127 is a critical-severity weak password recovery mechanism for forgotten password vulnerability in Security Gateway from Daikin Europe N.V, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Security Gateway versions: App: 100, Frm: 214. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.65% chance of exploitation within 30 days, higher than 52% of scored CVEs.
Critical severity: a successful attack would have severe impact.
What to do
- Check which version of Security Gateway you run against the affected versions below, and install the vendor's latest release.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Daikin Europe N.V | Security Gateway | App: 100, Frm: 214 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (hq.dhs.gov).
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 8.8 | High | CNA (hq.dhs.gov) |
| CVSS 3.1 | 9.8 | Critical | CNA (hq.dhs.gov) |
Official description
Daikin Europe N.V Security Gateway is vulnerable to an authorization bypass through a user-controlled key vulnerability that could allow an attacker to bypass authentication. An unauthorized attacker could access the system without prior credentials.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Weak Password Recovery Mechanism for Forgotten Password
The product contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak.
How developers prevent this class of flaw
- Make sure that all input supplied by the user to the password recovery mechanism is thoroughly filtered and validated.
- Do not use standard weak security questions and use several security questions.
- Make sure that there is throttling on the number of incorrect answers to a security question. Disable the password recovery functionality after a certain (small) number of incorrect guesses.
More Weak Password Recovery Mechanism for Forgotten Password vulnerabilities (CWE-640)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other references
Recent Weak Password Recovery Mechanism for Forgotten Password vulnerabilities
- 9.8 Critical severity
- 8.9 High severity
- 8.8 High severity
- 9.8 Critical severity
- 9.8 Critical severity
- 9.8 Critical severity
Spotted an error? Tell us.