CyberSecBulletin
CVE-2025-20265NVD status: Modified

Cisco Firepower Management Center: Improper Neutralization of Special Elements in Output Used by a Downstream Component

CVE-2025-20265 is a critical-severity improper neutralization of special elements in output used by a downstream component vulnerability in Cisco Firepower Management Center from Cisco, with a CVSS 3.1 base score of 10.0 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Cisco Firepower Management Center versions: 7.0.7; 7.7.0. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 15.9% chance of exploitation within 30 days, which is in the top 3.06% of all scored CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of Cisco Firepower Management Center you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on sec.cloudapps.cisco.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
CiscoCisco Firepower Management Center7.0.7; 7.7.0Not stated
CiscoSecure Firewall Management Center7.0.7; 7.7.0Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
ChangedThe attack can reach beyond the vulnerable component into other systems.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H. Scored by CNA (cisco.com).

Official description

A vulnerability in the RADIUS subsystem implementation of Cisco Secure Firewall Management Center (FMC) Software could allow an unauthenticated, remote attacker to inject arbitrary shell commands that are executed by the device.  This vulnerability is due to a lack of proper handling of user input during the authentication phase. An attacker could exploit this vulnerability by sending crafted input when entering credentials that will be authenticated at the configured RADIUS server. A successful exploit could allow the attacker to execute commands at a high privilege level. Note: For this vulnerability to be exploited, Cisco Secure FMC Software must be configured for RADIUS authentication for the web-based management interface, SSH management, or both.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements in Output Used by a Downstream Component

The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.

How developers prevent this class of flaw

  • Programming languages and supporting technologies might be chosen which are not subject to these issues.
  • Utilize an appropriate mix of allowlist and denylist parsing to filter control-plane syntax from all input.

More Improper Neutralization of Special Elements in Output Used by a Downstream Component vulnerabilities (CWE-74)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in Cisco Firepower Management Center

All Cisco Firepower Management Center vulnerabilities

Recent Improper Neutralization of Special Elements in Output Used by a Downstream Component vulnerabilities

Spotted an error? Tell us.