CyberSecBulletin
CVE-2025-23119NVD status: Deferred

UniFi Protect Cameras: Improper Neutralization of Special Elements used in a Command

CVE-2025-23119 is a high-severity improper neutralization of special elements used in a command vulnerability in UniFi Protect Cameras from Ubiquiti, with a CVSS 3.0 base score of 7.5 out of 10. It can be exploited from the same local network by an unauthenticated attacker, without any action from a user. The record lists version 4.74.106 as the first without the flaw, so updating UniFi Protect Cameras to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.71% chance of exploitation within 30 days, higher than 54% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update UniFi Protect Cameras to 4.74.106 or a later version.
  2. Read the advisory on community.ui.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
UbiquitiUniFi Protect Cameras4.74.106 up to, but not including, 4.74.1064.74.106

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
HighSuccess depends on conditions outside the attacker's control.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (hackerone.com).

Official description

An Improper Neutralization of Escape Sequences vulnerability could allow an Authentication Bypass with a Remote Code Execution (RCE) by a malicious actor with access to UniFi Protect Cameras adjacent network.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in a Command

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • If possible, ensure that all external commands called from the program are statically created.
  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.

More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in UniFi Protect Cameras

All UniFi Protect Cameras vulnerabilities

Recent Improper Neutralization of Special Elements used in a Command vulnerabilities

Spotted an error? Tell us.