CyberSecBulletin
CVE-2025-30115NVD status: Analyzed

Dr 820 Firmware: Use of Hard-coded Password

CVE-2025-30115 is a critical-severity use of hard-coded password vulnerability in Dr 820 Firmware from Hella, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. There is no confirmed exploitation so far. EPSS estimates a 0.45% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of Dr 820 Firmware you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
HellaDr 820 FirmwareNot specified in the recordNot stated

Version data comes from NVD's product matching. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CISA (ADP).

Official description

An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Default Credentials Cannot Be Changed. It uses a fixed default SSID and password ("qwertyuiop"), which cannot be modified by users. The SSID is continuously broadcast, allowing unauthorized access to the device network.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Use of Hard-coded Password

The product contains a hard-coded password, which it uses for its own inbound authentication or for outbound authentication to external components.

How developers prevent this class of flaw

  • For outbound authentication: store passwords outside of the code in a strongly-protected, encrypted configuration file or database that is protected from access by all outsiders, including other local users on the same system. Properly protect the key (CWE-320). If you cannot use encryption to protect the file, then make sure that the permissions are as restrictive as possible.
  • For inbound authentication: Rather than hard-code a default username and password for first time logins, utilize a first login mode that requires the user to enter a unique strong password.
  • Perform access control checks and limit which entities can access the feature that requires the hard-coded password. For example, a feature might only be enabled through the system console instead of through a network connection.

More Use of Hard-coded Password vulnerabilities (CWE-259)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Other vulnerabilities in Dr 820 Firmware

All Dr 820 Firmware vulnerabilities

Recent Use of Hard-coded Password vulnerabilities

Spotted an error? Tell us.