CyberSecBulletin
CVE-2025-31930NVD status: Deferred

IEC 1Ph 7.4kW Child socket: Initialization of a Resource with an Insecure Default

CVE-2025-31930 is a high-severity initialization of a resource with an insecure default vulnerability in IEC 1Ph 7.4kW Child socket from Siemens, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited from the same local network by an unauthenticated attacker, without any action from a user. The record lists version V2.135 as the first without the flaw, so updating IEC 1Ph 7.4kW Child socket to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.29% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update IEC 1Ph 7.4kW Child socket to V2.135 or a later version.
  2. Update IEC 1Ph 7.4kW Child socket/ shutter to V2.135 or a later version.
  3. Update IEC 1Ph 7.4kW Parent cable 7m to V2.135 or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensIEC 1Ph 7.4kW Child socketbefore V2.135V2.135
SiemensIEC 1Ph 7.4kW Child socket/ shutterbefore V2.135V2.135
SiemensIEC 1Ph 7.4kW Parent cable 7mbefore V2.135V2.135
SiemensIEC 1Ph 7.4kW Parent cable 7m incl. SIMbefore V2.135V2.135
SiemensIEC 1Ph 7.4kW Parent socketbefore V2.135V2.135
SiemensIEC 1Ph 7.4kW Parent socket incl. SIMbefore V2.135V2.135
SiemensIEC 1Ph 7.4kW Parent socket/ shutterbefore V2.135V2.135
SiemensIEC 1Ph 7.4kW Parent socket/ shutter SIMbefore V2.135V2.135
SiemensIEC 3Ph 22kW Child cable 7mbefore V2.135V2.135
SiemensIEC 3Ph 22kW Child socketbefore V2.135V2.135
SiemensIEC 3Ph 22kW Child socket/ shutterbefore V2.135V2.135
SiemensIEC 3Ph 22kW Parent cable 7mbefore V2.135V2.135
SiemensIEC 3Ph 22kW Parent cable 7m incl. SIMbefore V2.135V2.135
SiemensIEC 3Ph 22kW Parent socketbefore V2.135V2.135
SiemensIEC 3Ph 22kW Parent socket incl. SIMbefore V2.135V2.135
SiemensIEC 3Ph 22kW Parent socket/ shutterbefore V2.135V2.135
SiemensIEC 3Ph 22kW Parent socket/ shutter SIMbefore V2.135V2.135
SiemensIEC ERK 3Ph 22 kW Child cable 7mbefore V2.135V2.135
SiemensIEC ERK 3Ph 22 kW Child socketbefore V2.135V2.135
SiemensIEC ERK 3Ph 22 kW Parent socketbefore V2.135V2.135
SiemensIEC ERK 3Ph 22 kW Parent socket incl. SIbefore V2.135V2.135
SiemensUL Commercial Cellular 48A NTEPbefore V2.135V2.135
SiemensUL Commercial Child 40A w/ 15118 HWbefore V2.135V2.135
SiemensUL Commercial Child 48A BA Compliantbefore V2.135V2.135
SiemensUL Commercial Child 48A w/ 15118 HWbefore V2.135V2.135

Version data comes from the organisation that assigned the CVE; 7 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (siemens.com).

Scoring systemScoreSeverityScored by
CVSS 4.08.7HighCNA (siemens.com)
CVSS 3.18.8HighCNA (siemens.com)

Official description

A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Initialization of a Resource with an Insecure Default

The product initializes or sets a resource with a default that is intended to be changed by the product's installer, administrator, or maintainer, but the default is not secure.

More Initialization of a Resource with an Insecure Default vulnerabilities (CWE-1188)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Initialization of a Resource with an Insecure Default vulnerabilities

Spotted an error? Tell us.