CyberSecBulletin
CVE-2025-34082NVD status: Deferred

OS: Improper Neutralization of Special Elements used in an OS Command

CVE-2025-34082 is a critical-severity improper neutralization of special elements used in an OS command vulnerability in OS from IGEL Technology, with a CVSS 4.0 base score of 9.3 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists versions 11.04.270, 10.06.220 as the first without the flaw, so updating OS to one of those releases or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 6.59% chance of exploitation within 30 days, which is in the top 6.05% of all scored CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Update OS to 11.04.270 or 10.06.220, whichever matches your release line, or a later version.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
IGEL TechnologyOS11 up to, but not including, 11.04.270; 10 up to, but not including, 10.06.22011.04.270, 10.06.220

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Attack requirements
NoneThe attack does not depend on a particular deployment or configuration.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Confidentiality (vulnerable system)
HighSerious loss of confidentiality on the vulnerable system.
Integrity (vulnerable system)
HighSerious loss of integrity on the vulnerable system.
Availability (vulnerable system)
HighSerious loss of availability on the vulnerable system.
Confidentiality (other systems)
NoneNo loss of confidentiality on systems beyond the vulnerable one.
Integrity (other systems)
NoneNo loss of integrity on systems beyond the vulnerable one.
Availability (other systems)
NoneNo loss of availability on systems beyond the vulnerable one.

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA (vulncheck.com).

Official description

A command injection vulnerability exists in IGEL OS versions prior to 11.04.270 within the Secure Terminal and Secure Shadow services. The flaw arises due to improper input sanitization in the handling of specially crafted PROXYCMD commands on TCP ports 30022 and 5900. An unauthenticated attacker with network access to a vulnerable device can inject arbitrary commands, leading to remote code execution with elevated privileges. NOTE: IGEL OS v10.x has reached end-of-life (EOL) status.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in an OS Command

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • For any data that will be used to generate a command to be executed, keep as much of that data out of external control as possible. For example, in web applications, this may require storing the data locally in the session's state instead of sending it out to the client in a hidden form field.
  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

More Improper Neutralization of Special Elements used in an OS Command vulnerabilities (CWE-78)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Improper Neutralization of Special Elements used in an OS Command vulnerabilities

Spotted an error? Tell us.