CC-Link IE TSN Remote I/O module NZ2GN2S1-32D: Improper Validation of Specified Quantity in Input
CVE-2025-3511 is a high-severity improper validation of specified quantity in input vulnerability in CC-Link IE TSN Remote I/O module NZ2GN2S1-32D from Mitsubishi Electric, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected CC-Link IE TSN Remote I/O module NZ2GN2S1-32D versions: 09 and prior. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.93% chance of exploitation within 30 days, higher than 61% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of CC-Link IE TSN Remote I/O module NZ2GN2S1-32D you run against the affected versions below, and install the vendor's latest release.
- Read the advisory on mitsubishielectric.com for workarounds and exact fixed builds.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
Version data comes from the organisation that assigned the CVE; 24 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- NoneNo data is disclosed.
- Integrity
- NoneNothing can be modified.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Scored by CNA (yd.MitsubishiElectric.co.jp).
Official description
Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Validation of Specified Quantity in Input
The product receives input that is expected to specify a quantity (such as size or length), but it does not validate or incorrectly validates that the quantity has the required properties.
More Improper Validation of Specified Quantity in Input vulnerabilities (CWE-1284)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Recent Improper Validation of Specified Quantity in Input vulnerabilities
- 7.5 High severity
- 7.8 High severity
- 8.4 High severity
- 7.8 High severity
- 7.5 High severity
- 7.0 High severity
Spotted an error? Tell us.